Analog Devices' Smoke Detection Solutions

A Better Way to Design Smoke Detectors. A Better Way to Save Lives.

Smoke detectors save lives. Three of every five fire-related deaths in the U.S. occurred in properties without smoke detectors. Smoke detectors save lives, but only when they are used properly. In properties with smoke detectors, nearly one in four deaths (23%) occurred where smoke detectors were not working, or were disabled due to frequent false alarms.

Smoke detector manufacturers face four critical challenges:

  1. Higher performance to reduce the frequency of false alarms, which result in consumers disabling or turning off the units

  2. New regulatory requirements (UL217, EN54/14604)

  3. Power consumption that requires frequent battery replacement

  4. Reducing smoke detector size to enable easier architectural integration and aesthetic appeal

New solutions for smoke detection

Leveraging our deep sensor expertise, we can provide integrated solutions to help manufacturers engineer better smoke detectors.

Performance

Our integrated design uses two colors to separate particle sizes, increasing the ability to detect and classify smoke types and reject nuisance sources in challenging environments, such as kitchens and bathrooms

Regulation

The ADI module is engineered to help manufacturers meet UL217 requirements as well as EN54/14604 specifications.

Power

The analog front end (AFE) and integrated design result in better power management to extend battery life, allow for sensors, and support wireless product designs.

Size

  • Integrating circuitry and components allows for a smaller, simplified chamber design to improve manufacturing flow efficiency. It also reduces calibration requirements at production test and assembly

  • Contributing to a smaller footprint allows for sensors, wireless connectivity options, and other added value features

  • Facilitating a compact design reduces system cost and results in a smaller, more aesthetically pleasing detector

How it works

Analog Devices offers a solution that combines an analog front-end, LED, and photodiode into a small package, greatly reducing the smoke detector footprint. The integration of the photodiode and AFE also provides high ambient light rejection and wide dynamic range to better reduce false alarms.

adi-smoke-detetction-inset1

An integrated optical design greatly reduces the overall size of the smoke detector.

The ADI solution uses a Mie scattering approach with closer proximity of the LED to the photodiode. This reduces circuit board size and allows for smaller smoke detectors that are more architecturally compatible for residential and commercial use.

参阅相关产品

EVAL-ADPD188BIZ-S2

Analog Devices 传感器开发电路板和套件 查看

参阅相关产品

ADPD188BI-ACEZR7

Analog Devices 专用传感器 查看

参阅相关产品

EVAL-ADPDUCZ

Analog Devices 嵌入式系统开发板和套件 查看

参阅相关产品

EV-COG-AD4050LZ

Analog Devices 嵌入式系统开发板和套件 查看

参阅相关产品

ADP160AUJZ-1.8-R7

Analog Devices Linear Regulators 查看

参阅相关产品

LTC3427EDC#TRMPBF

Analog Devices 直流-直流转换器和开关调节器芯片 查看

参阅相关产品

LTC3531EDD-3.3#PBF

Analog Devices 直流-直流转换器和开关调节器芯片 查看

参阅相关产品

ADM7160ACPZN3.3-R7

Analog Devices Linear Regulators 查看

The infographic for smoke detection

A concise overview of the market challenges for smoke detector manufacturers and the solutions offered by ADI.

VIEW INFOGRAPHIC

相关新闻文章

最新消息

Sorry, your filter selection returned no results.

请仔细阅读我们近期更改的隐私政策。当按下确认键时,您已了解并同意艾睿电子的隐私政策和用户协议。

本网站需使用cookies以改善用户您的体验并进一步改进我们的网站。此处阅读了解关于网站cookies的使用以及如何禁用cookies。网页cookies和追踪功能或許用于市场分析。当您按下同意按钮,您已经了解并同意在您的设备上接受cookies,并给予网站追踪权限。更多关于如何取消网站cookies及追踪的信息,请点击下方“阅读更多”。尽管同意启用cookies追踪与否取决用户意愿,取消网页cookies及追踪可能导致网站运作或显示异常,亦或导致相关推荐广告减少。

我们尊重您的隐私。请在此阅读我们的隐私政策。