| Compliant with Exemption | |
| EAR99 | |
| Unconfirmed | |
| 8541.10.00.80 | |
| SVHC | Yes |
| SVHC 기준 초과 | Yes |
| Automotive | No |
| PPAP | No |
| Single | |
| Uni-Directional | |
| 1 | |
| 66.7 | |
| 97.3 | |
| 60 | |
| 154 | |
| 10 | |
| 5 | |
| 15000 | |
| -55 | |
| 175 | |
| Diameter | 9.1(Max) mm |
| Mounting | Through Hole |
| Package Length | 9.1(Max) mm |
| PCB changed | 2 |
| 2 |
Save yourself hassle by equipping your device with ProTek Devices' 15KPA60A-LF TVS diode which will react to sudden or momentary overvoltage conditions. Its maximum leakage current is 10 μA. Its peak pulse power dissipation is 15000 W. This device's maximum clamping voltage is 97.3 V and minimum breakdown voltage is 66.7 V. Its test current is 5 mA. This TVS diode has a minimum operating temperature of -55 °C and a maximum of 150 °C.