Product Technical Specifications
EU RoHS
Compliant
ECCN (US)
EAR99
Part Status
Active
HTS
8504.40.95.80
Automotive
No
PPAP
No
Type
Regulated
Style
Enclosed
Input/Output Type
AC/DC
Number of Outputs
1
Output Type
Fixed
Output Voltage (V)
48
Output Current (A)
25
Output Power (W)
1200
Minimum AC Input Voltage (V)
80
Typical AC Input Voltage (V)
100, 240
Maximum AC Input Voltage (V)
264
Minimum Isolation Voltage
4500VAC
Maximum Input Current (A)
14
Input Frequency (Hz)
47 to 63
Tolerance (%)
±1
Efficiency (%)
95(Typ)
Configurable
No
Input Connector Type
Spring Clamp Connector
Output Connector Type
Spring Clamp Connector
Power Indicator
Yes
Ripple and Noise
1%(Max)
Medical
No
Minimum Operating Temperature (°C)
-40
Maximum Operating Temperature (°C)
80
Packaging
Box
Product Weight (g)
1000
Mounting
Chassis
Package Height
40
Package Width
96.2
Package Length
228
Family/Series
RACM1200-48SAV/ENC
ROHS Version
2011/65/EU, 2015/863
MSL
1
Order Quantity